<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-11 05-13-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
87.90 MHz 5/5, 51 dBuV R-VYSOC
Pilot RDS Phase Difference
0.0 kHz 3.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
4 kHz 37 kHz 19000 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,8 dBr -1,11 dBr -0,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-VYSOC " 2D09 9 (Varied) 1 0 1 1 5:13, 11.04.2024
RT
"Cesky rozhlas Vysocina - zijeme tu s vami "
AF EON
87.9, 90.1, 96.5 MHz -
FM Scope Max at: 37 kHz MIN: 4 kHz % above 77 kHz: 0,0000 Acquired: 2024/04/11 5:13:37 Total samples: 19000 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,4 dBr MIN: -2,8 dBr AVE: -1,11 dBr % above 0,2 dBr: 0,0 Last value: -1,1 dBr (2024/04/11 5:13:36) 05:00 05:02 05:04 05:06 05:08 05:10 05:12 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality